GL860 Isolated multi-channel logger

GL860 Isolated multi-channel logger

€1,560.00

Isolated Expandable Multi-Input Datalogger

- +
SKU
GL860
Isolated/ Universal input, Expandable Multi-Input Datalogger midi LOGGER GL860. Suitable for temperature measurement with multiple channels
Item Description
Number of analog inputs Maximum 200ch available for 1 terminal(20ch/30ch) or extension unit
External input/
output  ※1
Input Trigger or Sampling (1 channel), Logic/Pulse (4 channels)
Voltage range :0 – +24V(common ground)  
Input signal: No-voltage contact (a-contact, b-contact, NO, NC), Open collector, Voltage input
Output Alarm (4ch)
Output signal: Open collector (pull-up to 5V by 10kΩ resistor)
Sampling interval 5ms – 1h(5ms – 50ms is available for voltage and humidity, Number of channels is limited, external※1
TIME / DIV 1s – 24h
Trigger function Repeat action Off・On
Trigger type Start: Data capture starts when a trigger is generated.
Stop: Data capture stops when a trigger is generated.
Trigger setting (Start / Stop)
Off, Level, Alarm, External, Time, Date, Week
Alarm function Alarm judgment mode Detection method: Level, Edge
Analog channel judgment mode: H (↑), L (↓), Window In, Window Out
Logic channel judgment mode: H (↑), L (↓)
Pulse channel judgment mode: H (↑), L (↓), Window In, Window Out
Calculation channel judgment mode: H (↑), L (↓), Window In, Window Out
Pulse input Measurement mode Rotation count (RPM) mode
Accumulating count mode
Instant count mode
Maximum number of pulse inputs Maximum input frequency : 50kHz
Maximum number of count : 50kC/sampling (16-bit counter)
PC I/F USB2.0 (Hi-speed), Ethernet (10BASE-T / 100BASE-TX), Wireless LAN(using B-568 option) 
* B-568 is available in limited region.
Storage
device
Internal Built-in 8GB Flash Memory *2
External *3 One SD card slot (Support SDHC memory card, up to 32GB) *2*3
Saved contents Setup conditions
Measured data
Screen copy
Operating environment 0 to 45 ºC, 5 to 85 % RH
(0 to 40°C when operated in batteries/15 to 35°C when a battery is charging)
Power supply AC adapter AC100 – 240V / 50 – 60Hz
DC input DC8.5 – 24V (Max. 26.4V)
Battery pack *Optional item DC7.2V (2875mAh) (*Two packs can be mounted)
Power consumption 36VA or lower (When using the AC adapter, the LCD is on, During
recharging battery, AC100V)
Vibration- tested conditions Equivalent to Equivalent to Automobile parts Type 1 Class A Buzzer

*1. Input/Output cable for GL (option B-513) is required.
*2. Each recorded file is limited to 2GB.
*3. When the wireless LAN (B-568, optional item) is installed, the SD memory card cannot be inserted into the SD CARD slot.

More Information
SKU GL860
Short Description

Isolated Expandable Multi-Input Datalogger

Options

Wireless LAN unit B-568 (option) specifications

Item Description
Model number B-568* Available in limited regions.
Communication method Wireless communication
Installation Mounted in SD CARD slot
* When the wireless unit is inserted, the SD memory card cannot be inserted into the SD CARD slot.
Wireless LAN standard IEEE802.11b / g / n
Function Control from PC, data transfer to PC, control and data transfer from smartphone/tablet
For access point: Local control and transfer are possible.
For station: In addition to local, remote control and transfer using G-REMOTE is also possible.
Communication range: Approx. 40 m
Communication range depends on the obstacles and the surrounding environmental conditions.
WPS: Push button method / PIN method
Encryption function: WEP64, WEP128, WPA-PSK/WPA 2-PSK (TKIP/AES)
WPA/WPA2 and TKIP/AES are automatically selected.

Humidity Sensor B-530 (option) Specifications

Item Description
Allowable temperature range –25 to +80°C
Allowable humidity range 0 to 100% RH
Relative humidity measurement accuracy ±3% RH (5 to 98% RH at 25°C)
Method Capacitance method
Relative humidity measurement accuracy
(5 to 98%)
Measurement environment Measurement accuracy
0 – 10℃ ±5% RH
1 – 20℃ ±4% RH
20 – 30℃ ±3% RH
30 – 40℃ ±4% RH
40 – 50℃ ±5% RH
50 – 60℃ ±6% RH
60 – 70℃ ±7% RH
70 – 80℃ ±8% RH
Measurement accuracy at 60°C or more is a reference value.
Response time 15 sec. (90% response when membrane filter is installed)
Sensor output 0 to 1 VDC
External dimensions φ14 × 80 mm (excluding cable)
Cable length 3m
Sensor power source DC+5V – +16V
Power consumption approx. 4 mA

*Only one B-530 can be connected to GL860