GL980 midi LOGGER, High-speed isolated 8-ch multifunction

GL980 midi LOGGER, High-speed isolated 8-ch multifunction

€3,600.00
We are out of stock, but you can back-order this product
Isolated simultaneous 8 channel Datalogger
- +
SKU
GL980

High Speed 1MS/s Datalogger with Voltage and Temperature Measurement Isolated simultaneous 8 channel data logger midi LOGGER GL980

Main Features:
High speed 1 MS/s simultaneous sampling with isolated input

GL980 is equipped with an isolated input mechanism to protect signals from interferrences caused by noise from other channels. 16-bit A/D converter adopted to achieve hi-speed and hi-resolution measurements.

  • Simultaneous sampling
    >GL980 utilizes simultaneous sampling to eliminate slowdown in sampling rate by using multiple A/D converters in simultaneous sampling method. Eight individual A/D converters in each channel sustains the maximum sampling speed for all eight channels to measure high speed rapid voltage fluctuation and multi-channel vibration measurement.
    Sampling interval: 1 µs to 1 min (in steps of 1, 2, 5)
  • External sampling function
    >Sampling of the logger is performed in sync with an external device using an external signal input.
    Maximum input frequency: 100 kHz    * B-513 Input/Output cable for GL is required.
Multifunction input

Voltage, temperature, humidity, logic and pulse measurements can all be taken simultaneously in high speed.

  • Measure repetitive waveforms such as vibration with instantaneous value and effective value.
    >Measures either instantaneous value or effective value (RMS). By utilizing the trigger feature to measure abnormal spikes in the continuous waveform, users can measure vibration abnormalities repeatedly.
  • Measures abnormalities in a repeated waveform by effectively measuring the corresponding RMS value.
    >All RMS measurement range with Crest Factor: up to 2
  • Scaling (Engineering unit) function
    >Measured voltage value can be converted to a specified engineering unit. The value can be displayed with the physical measurement value of the sensor and be saved into the data file with the converted values.
  • Calculation function between channels
    >Four arithmetic operations (Addition, subtraction, multiplication and division) are available using two analog input channels.
    * Data can be saved only in GBD file format.
  • Trigger function
    >The trigger in this unit has multiple functions including level trigger of input signal value for each channel.
  • Alarm function & signal output
    >Threshold of an alarm can be set for each channel. When an alarm occurs, notification is sent by following methods.
Large Easy-to-read 7-inch LCD

Monitor data in multiple methods in addition to digital value display and full waveform display screen.

  • Y-T waveform monitor screen
    >Displays data with analog waveform and digital value. Screen can also be split into 1, 2, 4 or 8 zones to display the channels in different zones.
  • Digital monitor screen
    >Displays current data in digital value and results of real time statistical calculation. (Function: Maximum, Minimum, Peak-to-peak, and Average)
    When displays only current data, it can be shown in 1, 2, 4 or 8 zones.
  • Past waveform monitor screen
    >Display the past part of the data while capturing data. Execute without stopping measurement and also scroll past data. Data screen can be switched with past and current.
  • XY graph monitor screen
    >Emulates the classic XY chart recorder. Also supports features for pen up/down and position movement.
Quick and Easy Set Up Process

Simple operation with cursor and enter keys, and menu-driven operation with six pre-set menu screens: AMP, DATA, DISP, TRIG, I/F (Interface) and OTHER.

Other helpful functions
  • Delivers reliable measurements out at a location with unstable power supply.
    >Equipped with three types of options for power source, AC adapter, DC input, and battery pack. With a battery pack, GL980 runs continuously for approximately 2 hours. If an AC power failure occurs, it will automatically switch from the AC adapter to the battery pack. Additionally, when the voltage of the battery pack reaches low, measurement is automatically stopped after saving the data file preserving the accumulated data. (Requires two battery packs (B-569 option) installed.)
Supports large built-in RAM (4MS/ch) and built-in Flash (4 GB)

Long term recording is made possible with 4 M samples/ch built-in RAM and 4 GB built-in Flash memory. It supports both USB Flash memory and SD Card memory to be used as external storage devices for recorded data for certain sampling intervals.

Approximate recording time
■ 8 channels of analog input. ■ Data is saved as a GBD file.

Memory type Data
capacity
1MS/s
(1μs)
100kS/s
(10μs)
1kS/s
(1ms)
1S/s
(1s)
Built-in RAM 4 M samples/ch 4 seconds 40 seconds 66 minutes 46 days
Built-in Flash memory 3.9 GB N/A N/A 2 days 6 hrs. Over 1 year
External memory (SD/USB Flash memory)* 4 GB N/A N/A 2 days 11 hrs. Over 1 year

 

■ 8 channels of analog input with 4 channels of Pulse input. ■ Data is saved as a GBD file.

Memory type Data
capacity
1MS/s
(1μs)
100kS/s
(10μs)
1kS/s
(1ms)
1S/s
(1s)
Built-in RAM 4 M samples/ch 4 seconds 40 seconds 66 minutes 46 days
Built-in Flash memory 3.9 GB N/A N/A 1 days 4 hrs. Over 1 year
External memory (SD/USB Flash memory)* 4 GB N/A N/A 1 days 7 hrs. Over 1 year

* When using 8 GB or larger memory, the size of data file will be up to 4 GB. The Relay mode enables extended recording time.

Convenient Data Recording Functions
  • Memory division function
    >Built-in RAM can be divided into 1, 2, 4, or 8 blocks with multiple high-speed recording measurement using the trigger function.
  • Ring mode
    >Saves most recent data of specified number after recording stops.
  • Relay mode
    >Save data to multiple files with specified capturing time or file size (up to 4 GB) until recording data is stopped.
  • Save & replay data in CSV format
    >Captured data can be saved with GBD (binary) and CSV (text) format. CSV format file can be played on GL980 and opened with spreadsheet software.
  • Data backup and hot swaps
    >he data file can be created periodically for purpose of backing up data while recording it, and the file is automatically transferred to another storage device on the unit or FTP server on the network.
    Backup interval: 1, 2, 6, 12, 24 hour(s). Backup file destination: Built-In Flash memory, SD memory card, USB memory device, FTP server
    Data file format: GBD (binary) or CSV (text)
    * The CSV format and FTP server are available with firmware version 1.14 or rater.
    −Available sampling speed is the 100 ms or slower when using the CSV format.
    −When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
    −The storage device specified as the recording destination of the measurement data can not be set as the transfer destination of the backup file.
    −When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
  • Auto save function
    >Recorded data saved in a built-in RAM is automatically copied as data file to a built-in Flash memory, SD Flash memory card or USB Flash memory with auto save function. An SD Flash memory card or a USB Flash memory can be used as a backup location when using the built-in RAM. The process will prevent losing any data captured in the built-in RAM by any overwrite or power cycles.
  • Search function
    >The search function can locate a specific value within the captured data as well as finding abnormal values within data of a long-recorded file.
Equipped with Ethernet (LAN) and USB interface to communicate with PC
  • Convenient function with LAN (Ethernet interface) capability
    >When GL980 is connected to LAN using the Ethernet interface, networked computer can monitor real-time measured value, transfer files, and change set ups without using application software (GL980_2000-APS software).
  • Web server function
    >GL980 can be controlled externally via a network on the WEB browser, which also supports real-time monitoring and ability to use the menu buttons.
  • FTP server function
    >File in available storage device on GL980 except built-in RAM can be transferred or deleted from the PC.
  • NTP client function
    >The clock on the GL980 is periodically synchronized with the NTP server.
  • Email sending function
    >Send information when alarm occurs, or when battery is low, or when communication speed drops, or to notify when the space becomes limited on the storage device by an e-mail to specified address. Information can also be sent periodically by settings.
  • USB Drive Mode to Easily Transfer Files to PC
    >The USB drive mode function allows simple data transfer to the PC from built-in Flash memory and SD Flash memory card which acts as USB Flash drive on GL980. It also allows to add, remove, and delete files from storage device on GL980 from PC file browsing explorer.

 

 

Item Description
Display (LCD) Size 7-inch TFT color LCD (WVGA: 800 x 480 dots)
Information Waveform in Y-T with digital values, Enlarged waveforms,
Digital values and Real-time statistical result values, XY graph
Language English, French, German, Spanish, Russian, Chinese, Korean, Japanese
Interface to PC Type Ethernet (10 BASE-T/100 BASE-TX), USB2.0
Function Data transfer to PC (up to 1 ms sampling), Control command to GL980
Ethernet functions Web server function, FTP server function, NTP client function,
DHCP client function, Email send function
USB function USB mode (File transfer and deletion from built-in flash and SD on GL980)
Trigger function Trigger action Start or stop capturing data by triggering
Trigger source • Start: Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
• Stop: Off, Measured signal, Alarm, External, Scheduled time, Scheduled day, Elapsed time
Combination Level OR, Level AND, Edge OR, Edge AND
Threshold • Analog (*1): High or Low in level mode, Rising or Falling in edge mode, Window-in,   Window-out
• Logic: H or L (4-channel signal pattern)
• Pulse: High or Rising, Low or Falling, Window-in, Window-out
Repeat action Off, On (Re-armed automatically)
Trigger hold out Hold off repeat action in specified period
• Mode: Previous start to next start, previous stop to next start
• Time: zero second (no hold off) to 9999 hrs. 59 min. 59 sec
Defection accuracy ± 0.5 % of measurement range
Pre-trigger Up to the number of capturing data points (max. 4000000)
specified in built-in RAM (only when built-in RAM is used)
Alarm function Alarm action Displays and outputs a signal when alarm is detected
Threshold • Analog input: High, Low, Window-in, Window-out
• Logic input: H or L (signal in each channel)
• Pulse input: High or Rising, Low or Falling, Window-in, Window-out
Combination OR (Source channel can be assigned with OR condition to output port)
Detection cycle Link with analog sampling
Alarm holding On or Off
Detection accuracy ± 0.5 % of measurement range
Storage deice Built-in RAM Four million samples for each channel
• Memory partition: 4 M samples x 1 bank, 2 M sample x 2 banks,
  1 M samples x 4 banks, 500 k samples x 8 banks
• Capturing data points: Specified 10 to 4000000
• Data type: Captured data
• Auto-save: Transfer captured data to other devices after capturing is completed
  (It can be enabled or disabled)
Built-in Flash 4 GB (for capacity of data: approx. 3.9 GB)
• Data type: Captured data, Condition settings, Screen copy
External USB (*2) Support USB Flash memory device (*3) by USB2.0 Type A port, Single port, No memory capacity limit
• Data type: Captured data, Condition settings, Screen copy
External
SD CARD (*2)
Support SDHC memory card (up to 32 GB) by SD Card slot, Single slot
• Data type: Captured data, Condition settings, Screen copy
Capturing mode Mode Off (Normal), Ring, Relay
Off (Normal) Save data between start to stop
Ring (*4) Save most recent data of specified number
• Destination: Built-in RAM, Built-in Flash, USB or SD
• Number of capturing data: 1000 to 10000000 data (*5)
• Sampling: up to 1 MS/s (interval 1 μs) in built-in RAM,
  up to 1 kS/s (interval 1 ms) with GBD format in other device,
  up to 100 S/s (interval 10 ms) with CSV format in other device
Relay Save data to multiple files with specified capturing time or file size (up to 4 GB) until recording data is stopped
• Destination: Built-in Flash, USB or SD
• Sampling: up to 1 kS/s (interval 1 ms) with GBD format,
  up to 100 S/s (interval 10 ms) with CSV format
Data backup Interval (*6) Off, 1, 2, 6, 12, 24 hrs., specific time, or any time with key operation
• Sampling: up to 1 kS/s (interval 1 ms) with GBD format,
  up to 100 S/s (interval 10 ms) with CSV format
File destination (*6) Built-in Flash, USB or SD, FTP
Data format (*6) GBD (binary) or CSV (test)
Hot-swapping
external memory
Hot-swapping USB or SD Flash memory with key operation during data backup
Search function Function Search for specific point in captured data
Search factor • Analog: Signal levels in each channel
• Logic: 4-channel signal pattern
• Pulse: Rising, Falling, Window-in, Window-out in each channel
• Alarm: Alarm occurring point
Calculation function Statistical Real-time: Display digital and statistical values at the same time
• Function: Maximum, Minimum, Peak-to-peak (P-P), Average
Replay: Statistical values between cursors in replay captured data
• Function: Maximum, Minimum, Peak-to-peak (P-P), Average, RMS
Between channels Addition, subtraction, multiplication and division for two analog inputs (only in GBD format)
Scaling (Engineering unit) function Measured value can be converted to the specified engineering unit
• Analog voltage: Converts using four reference points (gain, offset)
• Temperature: Converts using two reference points (offset)
• Pulse count: Converts using two reference points (gain)
Annotation function Comment can be set in each channel, up to 31 alphanumeric
characters and symbols (Display first 8 characters on screen)
Operating environment 0 to 40 ºC when driven by AC adapter or battery, 5 to 85 % RH (non condensed)
Power source AC adapter: 100 to 240 V AC, 50/60 Hz
DC power: 8.5 to 24 V DC (required cable option B-514)
Battery pack: Two battery packs (option B-569) required
Power consumption AC adapter
(in 240 V AC)
Approx. 48 VA (66 VA while charging battery) with disabling screen saver
Approx. 43 VA (62 VA while charging battery) with enabling screen saver
DC drive (24 V) Approx. 0.6 A (0.9 A while charging battery) with disable screen saver
Approx. 0.53 A (0.82 A while charging battery) with enabling screen saver
DC drive (12 V) Approx. 1.22 A (Cannot charge battery) with disable screen saver
Approx. 1.07 A (Cannot charge battery) with enabling screen saver
DC drive (8.5 V) Approx. 1.81 A (Cannot charge battery) with disable screen saver
Approx. 1.55 A (Cannot charge battery) with enabling screen saver
External dimensions [W×H×D] Approx. 260 x 161 x 83 mm (with the cover)
Weight Approx. 1.7 kg (the cover is attached, AC adapter and battery are not included)
Vibration resistance Compatible with JIS Vibration test method for automobile Type 1 Class A
(Vibration durability test: 5 m/s²)
(*1)
It can set for each channel.
(*2)
File size of captured data is up to 4GB in each file.
(*3)
Standard USB memory devices are required.
(*4)
Required minimum capturing time is 15 seconds in GBD format, 30 seconds with CSV format.
(*5)
When using built-in RAM, 10 to 4000000 data
(*6)
* The CSV format and FTP server are available with firmware version 1.14 or rater.<
- When the RING mode or external pulse synchronization sampling is selected for recording, the backup function is not available.
- When there are meany number of active channels, the sampling time is fast, or the backup interval is long, it may take time to closing the data file after recording stops because the size of the data to be backed up becomes large.
- When backup is enabled and data file format is specified with CSV format, SD memory card exchange (hot-swapping) and RELAY recording are not available.
More Information
SKU GL980
Short Description Isolated simultaneous 8 channel Datalogger